・Stable supply of temperature and pressure controlled dry clean air Can supply compressed air with the same conditions and quality regardless of the season ・Application example: Supplying compressed air with constant conditions to air bearings mounted on a tool ・Built-in filter Nominal filtration: 0.01 μm (99.9% filtration efficiency) Outlet oil mist concentration: Max. 0.01 mg/m3 (ANR) Outlet cleanliness: Particles of 0.3 μm or more: 3.5 particles/L (ANR) or less ・Compatible with power supplies from around the world Single-phase 100, 200, 230 VAC (50/60 Hz) |
Series | Air flow capacity L/min(ANR) | Outlet air temperature adjustment range | Outlet air set pressure range | Outlet air temperature stability | Temperature control method |
---|---|---|---|---|---|
IDH□4 | 100 to 500 | 15 to 30℃ | 0.15 to 0.85MPa | ±0.1 | Heater operation PID control |
IDH□6 | 200 to 800 | 15 to 30℃ | 0.15 to 0.85MPa | ±0.1 | Heater operation PID control |
Power failure auto-restart function
Even if operation is stopped by unexpected power failure, once the power supply is recovered, the operation will start automatically.
* If an instantaneous power failure occurs, the operation may restart after a few minutes.
Control temperature failure alarm
If the temperature exceeds the set temperature by an arbitrary amount, an error signal will be generated.
* At shipment, if the control temperature exceeds or goes under the set temperature by ±5ºC, an error signal will be generated.
Auto-tuning (A·T) function
The control set values (PID) are automatically set.
Key-lock function
The set value is protected so it will not be changed even if keys are touched by mistake or setting is changed.
Tags: Thermo-dryer with Air Temperature Adjustment Function IDH□